Argoclima AER522SCL3 Manual de servicio Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 82
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
11
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Part No. POWK228E
Controls Microprocessor
Control circuit fuse 250 V – 3.15 A
Remote Control Unit RCS8PS3E
Type Cross-flow
Q´ty ... Dia. and length mm 1 ... ø88 / L746
Fan motor model ... Q´ty UF2– 31A5PA–S ... 1
No. of poles ... rpm (High) 2 ... 1,380
Nominal output W 30
Coil resistance (Ambient temp. 20°C) WHT – BRN : 130.4
WHT – PNK : 169.8
– :
– :
– :
Safety
Type Thermal protector
devices Operating temp. Open °C 130 ± 8
Close Automatic reclosing
Run capacitor µF 2.0
VAC 440
Type Stepping motor
Model MP24GA2
Rating DC 12 V
Coil resistance (Ambient temp. 20°C) Each terminals (1–2, 1–3, 1–4, 1–5) 400 : ± 7%
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.3
Face area m2 0.250
Heat
Exch. Coil
Flap Motor Fan & Fan Motor
Circuit
Board
Ass´y
Indoor Unit AWR522CL
Vista de pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 81 82

Comentarios a estos manuales

Sin comentarios